The Honeywell Home Pro Series represents Resideo's professional contractor lineup, spanning modern push-button digital displays like the T4 Pro and T1 Pro, as well as legacy commercial PRO 1000, 2000, and 4000 series. This guide provides operating instructions, schedule programming procedures, and quick maintenance steps.

T4 Pro (TH4110U / TH4210U)

Push-button digital interface, flexible 7-day or 5-2 scheduling, standard UWP backplate, and 24VAC or AA battery power.

T1 Pro (TH1110D / TH1010D)

Non-programmable basic trade thermostat designed for straightforward manual temperature control without schedules.

Legacy PRO 1000 & 2000

Horizontal back-lit display models with simple slide switches for System (Heat/Off/Cool) and Fan (Auto/On).

How to Program Your Weekly Schedule (T4 Pro & Pro Series)

Honeywell Home Pro Series programmable models support up to 4 daily periods: Wake, Away, Home, and Sleep.

  1. Press the Menu button on the face of the thermostat.
  2. Press + or - until PROG or Schedule appears, then press Select.
  3. Select the target day group (e.g., Mon-Fri or individual days) and press Select.
  4. Use + or - to adjust the Wake time, then press Select.
  5. Adjust the heating and cooling setpoint temperatures for that period, then press Select.
  6. Repeat for Away, Home, and Sleep periods.
  7. Press Home or Done to save and activate the schedule.

Temperature Hold Settings Explained

Hold ModeHow to ActivateHow It OperatesHow to Cancel
Temporary HoldPress + or - arrow at any time.Maintains target temperature until the next scheduled period begins. Display shows "Temporary".Press Run Schedule or Cancel.
Permanent HoldPress + / -, then press the Hold button.Locks setpoint temperature indefinitely, overriding all programmed schedule blocks.Press Run Schedule or Hold to return to auto program.
Vacation / Away HoldMenu → Vacation Hold → Set Days.Maintains energy-saving temperature for a specified number of calendar days (1–99 days).Press Cancel on the main screen.

Honeywell T4 Pro (TH4110U) Key Installer Setup (ISU) Codes

To enter technician setup mode on a T4 Pro: Press and hold Menu and + simultaneously for 5 seconds until the screen changes.

ISU #Setting NameDefaultAvailable Parameter Options
120Schedule Options00 = Non-Prog; 2 = 5-2 Day (Weekday/Weekend); 3 = 5-1-1 Day; 4 = 7-Day Individual
200System Type11 = Conventional 1H/1C; 2 = Heat Pump (with auxiliary heat strips)
205Heating Equipment11 = Standard Gas Furnace; 2 = High Efficiency Gas (90%+); 3 = Electric Forced Air
218O/B Valve Orientation00 = O (Energized in Cool); 1 = B (Energized in Heat - Rheem/Ruud)
387Compressor Protection51 to 5 Minutes (Prevents compressor short cycling damage)
Embedded Manual Viewer: T4 Pro (TH4110U2005) / PRO 1000, 2000, 4000 Open Original PDF

Troubleshooting & System Diagnostics

Keypad Lock, Screen Unlocking & Diagnostics

How to Unlock a Locked Honeywell Pro Series Screen

If the screen shows a padlock icon and buttons do not respond, the keypad lockout is engaged:

  1. Press the Center button (or hold Menu and + for 5 seconds).
  2. Enter the 4-digit PIN (Default factory PIN is 1234 or calculate: 1234 + the 4-digit date code on backplate).
  3. Navigate to ISU setting 665 and set value to 0 (Unlocked).
  4. Press Select or Done.
How to Replace Batteries on Pro Series Models

When BATT or Low Batt appears on the display:

  • T-Series (T4 Pro / T1 Pro): Grasp the top and bottom of the housing and pull straight away from the wall mounting bracket. Replace with 2 fresh AA alkaline batteries and press the faceplate back until it clicks.
  • PRO 1000/2000 Series: Press down on the battery tray release tab on the top-right corner of the thermostat casing, slide the battery tray out, replace with 2 AAA batteries, and slide back in.
Related Honeywell Documentation